产品名称 Cyclic AMP EIA Kit from STRESSMARQ BIOSCIENCES INC.
产品货号 SKT-209-96
产品价格 现货询价,电话:010-67529703
产品规格 96 well
产品品牌 STRESSMARQ BIOSCIENCES INC.
产品概述
产品详情
Edit&nbsp
Product NameCyclic AMP EIA Kit
DescriptionThe Cyclic AMP EIA kit is designed to quantitatively measure cAMP present in lysed cells, EDTA and heparin plasma, urine, saliva and tissue culture media samples. For tissue samples, saliva and urine, where the levels of cAMP are expected to be relatively high, the regular format for the assay can be used. For plasma samples and some dilute cell lysates an optional acetylation protocol can be used. The kit is unique in that all samples and standards are diluted into an acidic Sample Diluent, which contains special additives and stabilizers, for cAMP measurement. This allows plasma, urine and saliva samples to be read in an identical manner to lysed cells. Acidified samples of cAMP are stable and endogenous phosphodiesterases are inactivated in the Sample Diluent. A cAMP standard is provided to generate a standard curve for the assay and all samples should be read off the standard curve. A clear microtiter plate coated with an antibody to capture sheep IgG is provided and a neutralizing Plate Primer solution is added to all the used wells. Standards or diluted samples, either with or without acetylation, are pipetted into the primed wells. A cAMP-peroxidase conjugate is added to the standards and samples in the wells. The binding reaction is initiated by the addition of a sheep antibody to cAMP to each well. After a 2 hour incubation, the plate is washed and substrate is added. The substrate reacts with the bound cAMP-peroxidase conjugate. After a short incubation, the reaction is stopped and the intensity of the generated color is detected in a microtiter plate reader capable of measuring 450 nm wavelength. The concentration of the cAMP in the sample is calculated, after making suitable correction for the dilution of the sample, using software available with most plate readers. Direct EIA (Enzyme Immunoassay). Intra Assay Precision (Regular): Three human urine samples were diluted with Sample Diluent and run in replicates of 20 in an assay. The mean and precision of the calculated cAMP concentrations were: Sample 1- 56.9 pmol/mL, 8.6% CV Sample 2- 11.9 pmol/mL, 11.3% CV Sample 3- 6.7 pmol/mL, 12.3% CV Intra Assay Precision (Acetylated): Two human plasma samples were diluted with Sample Diluent, acetylated and run in replicates of 20 in an assay. The mean and precision of the calculated cAMP concentrations were: Sample 1- 1.74 pmol/mL, 10.4% CV Sample 2- 0.60 pmol/mL, 11.8% CV Inter Assay Precision (Regular): Three human urine samples were diluted with Sample Diluent and run in duplicates in twelve assays run over multiple days by four operators. The mean and precision of the calculated cAMP concentrations were: Sample 1- 57.1 pmol/mL, 10.0% CV Sample 2- 10.9 pmol/mL, 11.5% CV Sample 3- 6.3 pmol/mL, 11.3% CV Inter Assay Precision (Acetylated): One human urine and two human plasma sample were diluted with Sample Diluent, acetylated and run in duplicates in twelve assays run over multiple days by four operators. The mean and precision of the calculated cAMP concentrations were: Sample 1- 5.22 pmol/mL, 9.8% CV Sample 2- 0.99 pmol/mL, 8.1% CV Sample 3- 0.73 pmol/mL, 15.4% CV. Range: Regular: 0.617 - 150 pmol/ml. Acetylated: 0.156 - 10 pmol/ml. Sensitivity: 0.64 pmol/ml. Time: 2.5 hours.
Size96 well
Concentrationn/a
ApplicationsEIA kit used to quantitatively measure cAMP present in samples. . RUO
Other NamesStressXpress® 3'-5'-cyclic adenosine monophosphate EIA Kit
Gene, Accession, CAS #n/a
Catalog #SKT-209-96
Price
Order / More InfoCyclic AMP EIA Kit from STRESSMARQ BIOSCIENCES INC.
Product Specific Referencesn/a
产品资料